✅ Solution:
Arrest any leakage in the system.
Check non-return valves (No. 37, 46) in pilot circuit (Q5 & Q9 pumps).
Clean and refit valves; replace if damaged.
Inspect flow regulator (No. 21); set flow to 15 l/min.
Check gauge No. 33 and replace if faulty.
Verify Q5 pump flow (15–23 l/min) at different RPMs.
Replace defective Q5 pump or coupling.
Adjust pressure regulator valve (No. 28) to 30 bar; replace if damaged